Respiratory mask testing according to EN 149: 2001 + A1: 2009

ffp-banner
Testing lab
Physical lab
Legislation
PPE Regulation (EU) 2016/425
Testing standard

EN 149: 2001 + A1: 2009

In order to CE mark an FFP or respiratory protection mask, the notified body must ensure that the performance criteria defined in EN 149: 2001 + A1: 2009 are met.

Centexbel is a laboratory accredited by BELAC to carry out the necessary tests.

Classification levels

EN 149: 2001 + A1: 2009 distinguishes between 3 levels of classification for FFP masks, including to the penetration level of the filter layer and breathing resistance of the mask:

Maximum penetration of test aerosol
Classification Sodium chloride test 95 l/min % Max. Paraffin oil test 85 l/min % Max.
FFP1 20 20
FFP2 6 6
FFP3 1 1
Maximum permitted resistance expressed in mbar
Max. permitted resitance (mbar)
inhalation exhalation
Classification 30 l/min 95 l/min 160 l/min
FFP1 0.6 2.1 3.0
FFP2 0.7 2.4 3.0
FFP3 1.0 3.0 3.0

EN149 consists of the following tests:

8.1 General

8.2 Visual inspection

8.3 Conditioning

8.4 Practical performance

8.5 Total Inward Leakage

8.6 Flammability

8.7 Carbon dioxide content of the inhalation air

8.8 Strength of attachment of exhalation valve housing

8.9 Breathing resistance

8.10 Clogging

8.11 Penetration of filter material

Video: 

EN 149 Exposure to penetration by sodium chloride

EN 149  Exposure to penetration by paraffin